USB: serial: keyspan: fix use-after-free in probe error path

The interface instat and indat URBs were submitted in attach, but never
unlinked in release before deallocating the corresponding transfer
buffers.

In the case of a late probe error (e.g. due to failed minor allocation),
disconnect would not have been called before release, causing the
buffers to be freed while the URBs are still in use. We'd also end up
with active URBs for an unbound interface.

Fixes: f9c99bb8b3a1 ("USB: usb-serial: replace shutdown with disconnect,
release")
Cc: stable <stable@vger.kernel.org>	# v2.6.31
Signed-off-by: Johan Hovold <johan@kernel.org>
Acked-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Johan Hovold 9 năm trước cách đây
mục cha
commit
35be1a71d7
1 tập tin đã thay đổi với 4 bổ sung0 xóa
  1. 4 0
      drivers/usb/serial/keyspan.c

+ 4 - 0
drivers/usb/serial/keyspan.c

@@ -2376,6 +2376,10 @@ static void keyspan_release(struct usb_serial *serial)
 
 	s_priv = usb_get_serial_data(serial);
 
+	/* Make sure to unlink the URBs submitted in attach. */
+	usb_kill_urb(s_priv->instat_urb);
+	usb_kill_urb(s_priv->indat_urb);
+
 	usb_free_urb(s_priv->instat_urb);
 	usb_free_urb(s_priv->indat_urb);
 	usb_free_urb(s_priv->glocont_urb);