浏览代码

net: phy: meson-gxl: leave CONFIG_A6 untouched

The PHY performs just as well when left in its default configuration and
it makes senses because this poke gets reset just after init.

According to the documentation, all registers in the Analog/DSP bank are
reset when there is a mode switch from 10BT to 100BT. The bank is also
reset on power down and soft reset, so we will never see the value which
may have been set by the bootloader.

In the end, we have used the default configuration so far and there is no
reason to change now. Remove CONFIG_A6 poke to make this clear.

Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Jerome Brunet <jbrunet@baylibre.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Jerome Brunet 7 年之前
父节点
当前提交
30e43f1334
共有 1 个文件被更改,包括 0 次插入9 次删除
  1. 0 9
      drivers/net/phy/meson-gxl.c

+ 0 - 9
drivers/net/phy/meson-gxl.c

@@ -38,9 +38,6 @@
 #define BANK_WOL		1
 #define BANK_BIST		3
 
-/* Analog/DSP Registers */
-#define A6_CONFIG_REG	0x17
-
 /* WOL Registers */
 #define LPI_STATUS	0xc
 #define  LPI_STATUS_RSV12	BIT(12)
@@ -126,12 +123,6 @@ static int meson_gxl_config_init(struct phy_device *phydev)
 {
 	int ret;
 
-	/* Write CONFIG_A6*/
-	ret = meson_gxl_write_reg(phydev, BANK_ANALOG_DSP, A6_CONFIG_REG,
-				  0x8e0d);
-	if (ret)
-		return ret;
-
 	/* Enable fractional PLL */
 	ret = meson_gxl_write_reg(phydev, BANK_BIST, FR_PLL_CONTROL, 0x5);
 	if (ret)