ソースを参照

vrf: check the original netdevice for generating redirect

Use the right device to determine if redirect should be sent especially
when using vrf. Same as well as when sending the redirect.

Signed-off-by: Stephen Suryaputra <ssuryaextr@gmail.com>
Acked-by: David Ahern <dsahern@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Stephen Suryaputra 7 年 前
コミット
2f17becfbe
2 ファイル変更8 行追加1 行削除
  1. 2 1
      net/ipv6/ip6_output.c
  2. 6 0
      net/ipv6/ndisc.c

+ 2 - 1
net/ipv6/ip6_output.c

@@ -482,7 +482,8 @@ int ip6_forward(struct sk_buff *skb)
 	   send redirects to source routed frames.
 	   We don't send redirects to frames decapsulated from IPsec.
 	 */
-	if (skb->dev == dst->dev && opt->srcrt == 0 && !skb_sec_path(skb)) {
+	if (IP6CB(skb)->iif == dst->dev->ifindex &&
+	    opt->srcrt == 0 && !skb_sec_path(skb)) {
 		struct in6_addr *target = NULL;
 		struct inet_peer *peer;
 		struct rt6_info *rt;

+ 6 - 0
net/ipv6/ndisc.c

@@ -1578,6 +1578,12 @@ void ndisc_send_redirect(struct sk_buff *skb, const struct in6_addr *target)
 	   ops_data_buf[NDISC_OPS_REDIRECT_DATA_SPACE], *ops_data = NULL;
 	bool ret;
 
+	if (netif_is_l3_master(skb->dev)) {
+		dev = __dev_get_by_index(dev_net(skb->dev), IPCB(skb)->iif);
+		if (!dev)
+			return;
+	}
+
 	if (ipv6_get_lladdr(dev, &saddr_buf, IFA_F_TENTATIVE)) {
 		ND_PRINTK(2, warn, "Redirect: no link-local address on %s\n",
 			  dev->name);