瀏覽代碼

dt-bindings: add device tree binding for Allwinner H6 main CCU

The Allwinner H6 main CCU uses the internal oscillator of the SoC, which
is different with old SoCs' main CCU.

Add device tree binding for the Allwinner H6 main CCU.

Signed-off-by: Icenowy Zheng <icenowy@aosc.io>
Signed-off-by: Maxime Ripard <maxime.ripard@bootlin.com>
Icenowy Zheng 7 年之前
父節點
當前提交
2e08e4d2ff
共有 1 個文件被更改,包括 4 次插入0 次删除
  1. 4 0
      Documentation/devicetree/bindings/clock/sunxi-ccu.txt

+ 4 - 0
Documentation/devicetree/bindings/clock/sunxi-ccu.txt

@@ -20,6 +20,7 @@ Required properties :
 		- "allwinner,sun50i-a64-ccu"
 		- "allwinner,sun50i-a64-ccu"
 		- "allwinner,sun50i-a64-r-ccu"
 		- "allwinner,sun50i-a64-r-ccu"
 		- "allwinner,sun50i-h5-ccu"
 		- "allwinner,sun50i-h5-ccu"
+		- "allwinner,sun50i-h6-ccu"
 		- "nextthing,gr8-ccu"
 		- "nextthing,gr8-ccu"
 
 
 - reg: Must contain the registers base address and length
 - reg: Must contain the registers base address and length
@@ -31,6 +32,9 @@ Required properties :
 - #clock-cells : must contain 1
 - #clock-cells : must contain 1
 - #reset-cells : must contain 1
 - #reset-cells : must contain 1
 
 
+For the main CCU on H6, one more clock is needed:
+- "iosc": the SoC's internal frequency oscillator
+
 For the PRCM CCUs on A83T/H3/A64, two more clocks are needed:
 For the PRCM CCUs on A83T/H3/A64, two more clocks are needed:
 - "pll-periph": the SoC's peripheral PLL from the main CCU
 - "pll-periph": the SoC's peripheral PLL from the main CCU
 - "iosc": the SoC's internal frequency oscillator
 - "iosc": the SoC's internal frequency oscillator