浏览代码

scsi: mpt3sas: Fix IO error occurs on pulling out a drive from RAID1 volume created on two SATA drive

Whenever an I/O for a RAID volume fails with IOCStatus
MPI2_IOCSTATUS_SCSI_IOC_TERMINATED and SCSIStatus equal to
(MPI2_SCSI_STATE_TERMINATED | MPI2_SCSI_STATE_NO_SCSI_STATUS) then
return the I/O to SCSI midlayer with "DID_RESET" (i.e. retry the IO
infinite times) set in the host byte.

Previously, the driver was completing the I/O with "DID_SOFT_ERROR"
which causes the I/O to be quickly retried. However, firmware needed
more time and hence I/Os were failing.

Signed-off-by: Sreekanth Reddy <Sreekanth.Reddy@broadcom.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
Sreekanth Reddy 7 年之前
父节点
当前提交
2ce9a36452
共有 1 个文件被更改,包括 5 次插入0 次删除
  1. 5 0
      drivers/scsi/mpt3sas/mpt3sas_scsih.c

+ 5 - 0
drivers/scsi/mpt3sas/mpt3sas_scsih.c

@@ -4807,6 +4807,11 @@ _scsih_io_done(struct MPT3SAS_ADAPTER *ioc, u16 smid, u8 msix_index, u32 reply)
 		} else if (log_info == VIRTUAL_IO_FAILED_RETRY) {
 			scmd->result = DID_RESET << 16;
 			break;
+		} else if ((scmd->device->channel == RAID_CHANNEL) &&
+		   (scsi_state == (MPI2_SCSI_STATE_TERMINATED |
+		   MPI2_SCSI_STATE_NO_SCSI_STATUS))) {
+			scmd->result = DID_RESET << 16;
+			break;
 		}
 		scmd->result = DID_SOFT_ERROR << 16;
 		break;