Parcourir la source

drivers/rtc/rtc-hym8563.c: set uie_unsupported

The alarm of the hym8563 only supports a minute accuracy, while the uie
wants an alarm one second in the future.  Therefore things like the
select() syscall will fail with a timeout, because the next alarm will
happen in a worst case of 60 seconds.

Signed-off-by: Heiko Stuebner <heiko@sntech.de>
Cc: Alessandro Zummo <a.zummo@towertech.it>
Cc: <stable@vger.kernel.org>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Heiko Stuebner il y a 11 ans
Parent
commit
282cba6b00
1 fichiers modifiés avec 3 ajouts et 0 suppressions
  1. 3 0
      drivers/rtc/rtc-hym8563.c

+ 3 - 0
drivers/rtc/rtc-hym8563.c

@@ -569,6 +569,9 @@ static int hym8563_probe(struct i2c_client *client,
 	if (IS_ERR(hym8563->rtc))
 		return PTR_ERR(hym8563->rtc);
 
+	/* the hym8563 alarm only supports a minute accuracy */
+	hym8563->rtc->uie_unsupported = 1;
+
 #ifdef CONFIG_COMMON_CLK
 	hym8563_clkout_register_clk(hym8563);
 #endif