瀏覽代碼

mmc: host: omap_hsmmc: reset cmd line on ceb error

When CEB (command end bit error) occurs
reset CMD line to avoid system ending up in
erroneous state.
While command line is reset for CTO and CCRC errors,
it's not done for CEB error. Fix it here.

Reviewed-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Ravikumar Kattekola <rk@ti.com>
Signed-off-by: Sekhar Nori <nsekhar@ti.com>
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
Ravikumar Kattekola 8 年之前
父節點
當前提交
24380dd4f8
共有 1 個文件被更改,包括 1 次插入1 次删除
  1. 1 1
      drivers/mmc/host/omap_hsmmc.c

+ 1 - 1
drivers/mmc/host/omap_hsmmc.c

@@ -1162,7 +1162,7 @@ static void omap_hsmmc_do_irq(struct omap_hsmmc_host *host, int status)
 	if (status & ERR_EN) {
 		omap_hsmmc_dbg_report_irq(host, status);
 
-		if (status & (CTO_EN | CCRC_EN))
+		if (status & (CTO_EN | CCRC_EN | CEB_EN))
 			end_cmd = 1;
 		if (host->data || host->response_busy) {
 			end_trans = !end_cmd;