Browse Source

bnxt_en: fix clear flags in ethtool reset handling

Clear flags when reset command processed successfully for components
specified.

Fixes: 6502ad5963a5 ("bnxt_en: Add ETH_RESET_AP support")
Signed-off-by: Scott Branden <scott.branden@broadcom.com>
Signed-off-by: Michael Chan <michael.chan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Scott Branden 7 years ago
parent
commit
2373d8d6a7
1 changed files with 6 additions and 2 deletions
  1. 6 2
      drivers/net/ethernet/broadcom/bnxt/bnxt_ethtool.c

+ 6 - 2
drivers/net/ethernet/broadcom/bnxt/bnxt_ethtool.c

@@ -2535,16 +2535,20 @@ static int bnxt_reset(struct net_device *dev, u32 *flags)
 			return -EOPNOTSUPP;
 
 		rc = bnxt_firmware_reset(dev, BNXT_FW_RESET_CHIP);
-		if (!rc)
+		if (!rc) {
 			netdev_info(dev, "Reset request successful. Reload driver to complete reset\n");
+			*flags = 0;
+		}
 	} else if (*flags == ETH_RESET_AP) {
 		/* This feature is not supported in older firmware versions */
 		if (bp->hwrm_spec_code < 0x10803)
 			return -EOPNOTSUPP;
 
 		rc = bnxt_firmware_reset(dev, BNXT_FW_RESET_AP);
-		if (!rc)
+		if (!rc) {
 			netdev_info(dev, "Reset Application Processor request successful.\n");
+			*flags = 0;
+		}
 	} else {
 		rc = -EINVAL;
 	}