@@ -24,10 +24,7 @@
|
|
#include <linux/of_device.h>
|
|
#include <linux/of_device.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/thermal.h>
|
|
|
|
|
|
-#define THERMAL_VALID_OFFSET 9
|
|
|
|
#define THERMAL_VALID_MASK 0x1
|
|
#define THERMAL_VALID_MASK 0x1
|
|
-#define THERMAL_TEMP_OFFSET 10
|
|
|
|
-#define THERMAL_TEMP_MASK 0x1ff
|
|
|
|
|
|
|
|
/* Thermal Manager Control and Status Register */
|
|
/* Thermal Manager Control and Status Register */
|
|
#define PMU_TDC0_SW_RST_MASK (0x1 << 1)
|
|
#define PMU_TDC0_SW_RST_MASK (0x1 << 1)
|
|
@@ -58,6 +55,11 @@ struct armada_thermal_data {
|
|
unsigned long coef_b;
|
|
unsigned long coef_b;
|
|
unsigned long coef_m;
|
|
unsigned long coef_m;
|
|
unsigned long coef_div;
|
|
unsigned long coef_div;
|
|
|
|
+
|
|
|
|
+ /* Register shift and mask to access the sensor temperature */
|
|
|
|
+ unsigned int temp_shift;
|
|
|
|
+ unsigned int temp_mask;
|
|
|
|
+ unsigned int is_valid_shift;
|
|
};
|
|
};
|
|
|
|
|
|
static void armadaxp_init_sensor(struct armada_thermal_priv *priv)
|
|
static void armadaxp_init_sensor(struct armada_thermal_priv *priv)
|
|
@@ -108,7 +110,7 @@ static bool armada_is_valid(struct armada_thermal_priv *priv)
|
|
{
|
|
{
|
|
unsigned long reg = readl_relaxed(priv->sensor);
|
|
unsigned long reg = readl_relaxed(priv->sensor);
|
|
|
|
|
|
- return (reg >> THERMAL_VALID_OFFSET) & THERMAL_VALID_MASK;
|
|
|
|
|
|
+ return (reg >> priv->data->is_valid_shift) & THERMAL_VALID_MASK;
|
|
}
|
|
}
|
|
|
|
|
|
static int armada_get_temp(struct thermal_zone_device *thermal,
|
|
static int armada_get_temp(struct thermal_zone_device *thermal,
|
|
@@ -126,7 +128,7 @@ static int armada_get_temp(struct thermal_zone_device *thermal,
|
|
}
|
|
}
|
|
|
|
|
|
reg = readl_relaxed(priv->sensor);
|
|
reg = readl_relaxed(priv->sensor);
|
|
- reg = (reg >> THERMAL_TEMP_OFFSET) & THERMAL_TEMP_MASK;
|
|
|
|
|
|
+ reg = (reg >> priv->data->temp_shift) & priv->data->temp_mask;
|
|
|
|
|
|
/* Get formula coeficients */
|
|
/* Get formula coeficients */
|
|
b = priv->data->coef_b;
|
|
b = priv->data->coef_b;
|
|
@@ -143,6 +145,8 @@ static struct thermal_zone_device_ops ops = {
|
|
|
|
|
|
static const struct armada_thermal_data armadaxp_data = {
|
|
static const struct armada_thermal_data armadaxp_data = {
|
|
.init_sensor = armadaxp_init_sensor,
|
|
.init_sensor = armadaxp_init_sensor,
|
|
|
|
+ .temp_shift = 10,
|
|
|
|
+ .temp_mask = 0x1ff,
|
|
.coef_b = 3153000000UL,
|
|
.coef_b = 3153000000UL,
|
|
.coef_m = 10000000UL,
|
|
.coef_m = 10000000UL,
|
|
.coef_div = 13825,
|
|
.coef_div = 13825,
|
|
@@ -151,6 +155,9 @@ static const struct armada_thermal_data armadaxp_data = {
|
|
static const struct armada_thermal_data armada370_data = {
|
|
static const struct armada_thermal_data armada370_data = {
|
|
.is_valid = armada_is_valid,
|
|
.is_valid = armada_is_valid,
|
|
.init_sensor = armada370_init_sensor,
|
|
.init_sensor = armada370_init_sensor,
|
|
|
|
+ .is_valid_shift = 9,
|
|
|
|
+ .temp_shift = 10,
|
|
|
|
+ .temp_mask = 0x1ff,
|
|
.coef_b = 3153000000UL,
|
|
.coef_b = 3153000000UL,
|
|
.coef_m = 10000000UL,
|
|
.coef_m = 10000000UL,
|
|
.coef_div = 13825,
|
|
.coef_div = 13825,
|