@@ -662,22 +662,25 @@ static int bq24190_charger_get_health(struct bq24190_dev_info *bdi,
|
|
|
v = bdi->f_reg;
|
|
|
mutex_unlock(&bdi->f_reg_lock);
|
|
|
|
|
|
- if (v & BQ24190_REG_F_BOOST_FAULT_MASK) {
|
|
|
- /*
|
|
|
- * This could be over-current or over-voltage but there's
|
|
|
- * no way to tell which. Return 'OVERVOLTAGE' since there
|
|
|
- * isn't an 'OVERCURRENT' value defined that we can return
|
|
|
- * even if it was over-current.
|
|
|
- */
|
|
|
- health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
|
|
|
- } else {
|
|
|
- v &= BQ24190_REG_F_CHRG_FAULT_MASK;
|
|
|
- v >>= BQ24190_REG_F_CHRG_FAULT_SHIFT;
|
|
|
-
|
|
|
- switch (v) {
|
|
|
- case 0x0: /* Normal */
|
|
|
- health = POWER_SUPPLY_HEALTH_GOOD;
|
|
|
+ if (v & BQ24190_REG_F_NTC_FAULT_MASK) {
|
|
|
+ switch (v >> BQ24190_REG_F_NTC_FAULT_SHIFT & 0x7) {
|
|
|
+ case 0x1: /* TS1 Cold */
|
|
|
+ case 0x3: /* TS2 Cold */
|
|
|
+ case 0x5: /* Both Cold */
|
|
|
+ health = POWER_SUPPLY_HEALTH_COLD;
|
|
|
break;
|
|
|
+ case 0x2: /* TS1 Hot */
|
|
|
+ case 0x4: /* TS2 Hot */
|
|
|
+ case 0x6: /* Both Hot */
|
|
|
+ health = POWER_SUPPLY_HEALTH_OVERHEAT;
|
|
|
+ break;
|
|
|
+ default:
|
|
|
+ health = POWER_SUPPLY_HEALTH_UNKNOWN;
|
|
|
+ }
|
|
|
+ } else if (v & BQ24190_REG_F_BAT_FAULT_MASK) {
|
|
|
+ health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
|
|
|
+ } else if (v & BQ24190_REG_F_CHRG_FAULT_MASK) {
|
|
|
+ switch (v >> BQ24190_REG_F_CHRG_FAULT_SHIFT & 0x3) {
|
|
|
case 0x1: /* Input Fault (VBUS OVP or VBAT<VBUS<3.8V) */
|
|
|
/*
|
|
|
* This could be over-voltage or under-voltage
|
|
@@ -694,9 +697,19 @@ static int bq24190_charger_get_health(struct bq24190_dev_info *bdi,
|
|
|
case 0x3: /* Charge Safety Timer Expiration */
|
|
|
health = POWER_SUPPLY_HEALTH_SAFETY_TIMER_EXPIRE;
|
|
|
break;
|
|
|
- default:
|
|
|
- health = POWER_SUPPLY_HEALTH_UNKNOWN;
|
|
|
+ default: /* prevent compiler warning */
|
|
|
+ health = -1;
|
|
|
}
|
|
|
+ } else if (v & BQ24190_REG_F_BOOST_FAULT_MASK) {
|
|
|
+ /*
|
|
|
+ * This could be over-current or over-voltage but there's
|
|
|
+ * no way to tell which. Return 'OVERVOLTAGE' since there
|
|
|
+ * isn't an 'OVERCURRENT' value defined that we can return
|
|
|
+ * even if it was over-current.
|
|
|
+ */
|
|
|
+ health = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
|
|
|
+ } else {
|
|
|
+ health = POWER_SUPPLY_HEALTH_GOOD;
|
|
|
}
|
|
|
|
|
|
val->intval = health;
|
|
@@ -707,19 +720,59 @@ static int bq24190_charger_get_health(struct bq24190_dev_info *bdi,
|
|
|
static int bq24190_charger_get_online(struct bq24190_dev_info *bdi,
|
|
|
union power_supply_propval *val)
|
|
|
{
|
|
|
- u8 v;
|
|
|
+ u8 pg_stat, batfet_disable;
|
|
|
int ret;
|
|
|
|
|
|
ret = bq24190_read_mask(bdi, BQ24190_REG_SS,
|
|
|
BQ24190_REG_SS_PG_STAT_MASK,
|
|
|
- BQ24190_REG_SS_PG_STAT_SHIFT, &v);
|
|
|
+ BQ24190_REG_SS_PG_STAT_SHIFT, &pg_stat);
|
|
|
if (ret < 0)
|
|
|
return ret;
|
|
|
|
|
|
- val->intval = v;
|
|
|
+ ret = bq24190_read_mask(bdi, BQ24190_REG_MOC,
|
|
|
+ BQ24190_REG_MOC_BATFET_DISABLE_MASK,
|
|
|
+ BQ24190_REG_MOC_BATFET_DISABLE_SHIFT, &batfet_disable);
|
|
|
+ if (ret < 0)
|
|
|
+ return ret;
|
|
|
+
|
|
|
+ val->intval = pg_stat && !batfet_disable;
|
|
|
+
|
|
|
return 0;
|
|
|
}
|
|
|
|
|
|
+static int bq24190_battery_set_online(struct bq24190_dev_info *bdi,
|
|
|
+ const union power_supply_propval *val);
|
|
|
+static int bq24190_battery_get_status(struct bq24190_dev_info *bdi,
|
|
|
+ union power_supply_propval *val);
|
|
|
+static int bq24190_battery_get_temp_alert_max(struct bq24190_dev_info *bdi,
|
|
|
+ union power_supply_propval *val);
|
|
|
+static int bq24190_battery_set_temp_alert_max(struct bq24190_dev_info *bdi,
|
|
|
+ const union power_supply_propval *val);
|
|
|
+
|
|
|
+static int bq24190_charger_set_online(struct bq24190_dev_info *bdi,
|
|
|
+ const union power_supply_propval *val)
|
|
|
+{
|
|
|
+ return bq24190_battery_set_online(bdi, val);
|
|
|
+}
|
|
|
+
|
|
|
+static int bq24190_charger_get_status(struct bq24190_dev_info *bdi,
|
|
|
+ union power_supply_propval *val)
|
|
|
+{
|
|
|
+ return bq24190_battery_get_status(bdi, val);
|
|
|
+}
|
|
|
+
|
|
|
+static int bq24190_charger_get_temp_alert_max(struct bq24190_dev_info *bdi,
|
|
|
+ union power_supply_propval *val)
|
|
|
+{
|
|
|
+ return bq24190_battery_get_temp_alert_max(bdi, val);
|
|
|
+}
|
|
|
+
|
|
|
+static int bq24190_charger_set_temp_alert_max(struct bq24190_dev_info *bdi,
|
|
|
+ const union power_supply_propval *val)
|
|
|
+{
|
|
|
+ return bq24190_battery_set_temp_alert_max(bdi, val);
|
|
|
+}
|
|
|
+
|
|
|
static int bq24190_charger_get_current(struct bq24190_dev_info *bdi,
|
|
|
union power_supply_propval *val)
|
|
|
{
|
|
@@ -834,6 +887,12 @@ static int bq24190_charger_get_property(struct power_supply *psy,
|
|
|
case POWER_SUPPLY_PROP_ONLINE:
|
|
|
ret = bq24190_charger_get_online(bdi, val);
|
|
|
break;
|
|
|
+ case POWER_SUPPLY_PROP_STATUS:
|
|
|
+ ret = bq24190_charger_get_status(bdi, val);
|
|
|
+ break;
|
|
|
+ case POWER_SUPPLY_PROP_TEMP_ALERT_MAX:
|
|
|
+ ret = bq24190_charger_get_temp_alert_max(bdi, val);
|
|
|
+ break;
|
|
|
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
|
|
|
ret = bq24190_charger_get_current(bdi, val);
|
|
|
break;
|
|
@@ -882,6 +941,12 @@ static int bq24190_charger_set_property(struct power_supply *psy,
|
|
|
return ret;
|
|
|
|
|
|
switch (psp) {
|
|
|
+ case POWER_SUPPLY_PROP_ONLINE:
|
|
|
+ ret = bq24190_charger_set_online(bdi, val);
|
|
|
+ break;
|
|
|
+ case POWER_SUPPLY_PROP_TEMP_ALERT_MAX:
|
|
|
+ ret = bq24190_charger_set_temp_alert_max(bdi, val);
|
|
|
+ break;
|
|
|
case POWER_SUPPLY_PROP_CHARGE_TYPE:
|
|
|
ret = bq24190_charger_set_charge_type(bdi, val);
|
|
|
break;
|
|
@@ -907,6 +972,8 @@ static int bq24190_charger_property_is_writeable(struct power_supply *psy,
|
|
|
int ret;
|
|
|
|
|
|
switch (psp) {
|
|
|
+ case POWER_SUPPLY_PROP_ONLINE:
|
|
|
+ case POWER_SUPPLY_PROP_TEMP_ALERT_MAX:
|
|
|
case POWER_SUPPLY_PROP_CHARGE_TYPE:
|
|
|
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
|
|
|
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE:
|
|
@@ -923,6 +990,8 @@ static enum power_supply_property bq24190_charger_properties[] = {
|
|
|
POWER_SUPPLY_PROP_CHARGE_TYPE,
|
|
|
POWER_SUPPLY_PROP_HEALTH,
|
|
|
POWER_SUPPLY_PROP_ONLINE,
|
|
|
+ POWER_SUPPLY_PROP_STATUS,
|
|
|
+ POWER_SUPPLY_PROP_TEMP_ALERT_MAX,
|
|
|
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT,
|
|
|
POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX,
|
|
|
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
|
|
@@ -1096,6 +1165,7 @@ static int bq24190_battery_get_property(struct power_supply *psy,
|
|
|
struct bq24190_dev_info *bdi = power_supply_get_drvdata(psy);
|
|
|
int ret;
|
|
|
|
|
|
+ dev_warn(bdi->dev, "warning: /sys/class/power_supply/bq24190-battery is deprecated\n");
|
|
|
dev_dbg(bdi->dev, "prop: %d\n", psp);
|
|
|
|
|
|
ret = pm_runtime_get_sync(bdi->dev);
|
|
@@ -1141,6 +1211,7 @@ static int bq24190_battery_set_property(struct power_supply *psy,
|
|
|
struct bq24190_dev_info *bdi = power_supply_get_drvdata(psy);
|
|
|
int ret;
|
|
|
|
|
|
+ dev_warn(bdi->dev, "warning: /sys/class/power_supply/bq24190-battery is deprecated\n");
|
|
|
dev_dbg(bdi->dev, "prop: %d\n", psp);
|
|
|
|
|
|
ret = pm_runtime_get_sync(bdi->dev);
|
|
@@ -1269,9 +1340,9 @@ static void bq24190_check_status(struct bq24190_dev_info *bdi)
|
|
|
bdi->ss_reg = ss_reg;
|
|
|
}
|
|
|
|
|
|
- if (alert_charger)
|
|
|
+ if (alert_charger || alert_battery)
|
|
|
power_supply_changed(bdi->charger);
|
|
|
- if (alert_battery)
|
|
|
+ if (alert_battery && bdi->battery)
|
|
|
power_supply_changed(bdi->battery);
|
|
|
|
|
|
dev_dbg(bdi->dev, "ss_reg: 0x%02x, f_reg: 0x%02x\n", ss_reg, f_reg);
|
|
@@ -1476,19 +1547,23 @@ static int bq24190_probe(struct i2c_client *client,
|
|
|
goto out_pmrt;
|
|
|
}
|
|
|
|
|
|
- battery_cfg.drv_data = bdi;
|
|
|
- bdi->battery = power_supply_register(dev, &bq24190_battery_desc,
|
|
|
- &battery_cfg);
|
|
|
- if (IS_ERR(bdi->battery)) {
|
|
|
- dev_err(dev, "Can't register battery\n");
|
|
|
- ret = PTR_ERR(bdi->battery);
|
|
|
- goto out_charger;
|
|
|
+ /* the battery class is deprecated and will be removed. */
|
|
|
+ /* in the interim, this property hides it. */
|
|
|
+ if (!device_property_read_bool(dev, "omit-battery-class")) {
|
|
|
+ battery_cfg.drv_data = bdi;
|
|
|
+ bdi->battery = power_supply_register(dev, &bq24190_battery_desc,
|
|
|
+ &battery_cfg);
|
|
|
+ if (IS_ERR(bdi->battery)) {
|
|
|
+ dev_err(dev, "Can't register battery\n");
|
|
|
+ ret = PTR_ERR(bdi->battery);
|
|
|
+ goto out_charger;
|
|
|
+ }
|
|
|
}
|
|
|
|
|
|
ret = bq24190_sysfs_create_group(bdi);
|
|
|
if (ret) {
|
|
|
dev_err(dev, "Can't create sysfs entries\n");
|
|
|
- goto out_battery;
|
|
|
+ goto out_charger;
|
|
|
}
|
|
|
|
|
|
bdi->initialized = true;
|
|
@@ -1526,10 +1601,9 @@ static int bq24190_probe(struct i2c_client *client,
|
|
|
out_sysfs:
|
|
|
bq24190_sysfs_remove_group(bdi);
|
|
|
|
|
|
-out_battery:
|
|
|
- power_supply_unregister(bdi->battery);
|
|
|
-
|
|
|
out_charger:
|
|
|
+ if (!IS_ERR_OR_NULL(bdi->battery))
|
|
|
+ power_supply_unregister(bdi->battery);
|
|
|
power_supply_unregister(bdi->charger);
|
|
|
|
|
|
out_pmrt:
|
|
@@ -1552,7 +1626,8 @@ static int bq24190_remove(struct i2c_client *client)
|
|
|
|
|
|
bq24190_register_reset(bdi);
|
|
|
bq24190_sysfs_remove_group(bdi);
|
|
|
- power_supply_unregister(bdi->battery);
|
|
|
+ if (bdi->battery)
|
|
|
+ power_supply_unregister(bdi->battery);
|
|
|
power_supply_unregister(bdi->charger);
|
|
|
if (error >= 0)
|
|
|
pm_runtime_put_sync(bdi->dev);
|
|
@@ -1639,7 +1714,8 @@ static __maybe_unused int bq24190_pm_resume(struct device *dev)
|
|
|
|
|
|
/* Things may have changed while suspended so alert upper layer */
|
|
|
power_supply_changed(bdi->charger);
|
|
|
- power_supply_changed(bdi->battery);
|
|
|
+ if (bdi->battery)
|
|
|
+ power_supply_changed(bdi->battery);
|
|
|
|
|
|
return 0;
|
|
|
}
|