Browse Source

thermal: rockchip: fix calculation error for code_to_temp

the calculation use a global table, not their own table.
so adapt the table to the correct one.

Signed-off-by: Elaine Zhang <zhangqing@rock-chips.com>
Signed-off-by: Caesar Wang <wxt@rock-chips.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Elaine Zhang 9 years ago
parent
commit
1d37a037dd
1 changed files with 1 additions and 1 deletions
  1. 1 1
      drivers/thermal/rockchip_thermal.c

+ 1 - 1
drivers/thermal/rockchip_thermal.c

@@ -411,7 +411,7 @@ static int rk_tsadcv2_code_to_temp(struct chip_tsadc_table table, u32 code,
 	 * temperature between 2 table entries is linear and interpolate
 	 * to produce less granular result.
 	 */
-	num = table.id[mid].temp - v2_code_table[mid - 1].temp;
+	num = table.id[mid].temp - table.id[mid - 1].temp;
 	num *= abs(table.id[mid - 1].code - code);
 	denom = abs(table.id[mid - 1].code - table.id[mid].code);
 	*temp = table.id[mid - 1].temp + (num / denom);