Эх сурвалжийг харах

clk: exynos5433: Fix CLK_PCLK_MONOTONIC_CNT clk register assignment

CLK_PCLK_MONOTONIC_CNT clock had a wrong register assigned to it.
The correct register is ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT.

Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com>
Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski.k@gmail.com>
Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Jonghwa Lee 10 жил өмнө
parent
commit
1a9f6c887d

+ 1 - 1
drivers/clk/samsung/clk-exynos5433.c

@@ -1490,7 +1490,7 @@ static struct samsung_gate_clock mif_gate_clks[] __initdata = {
 
 	/* ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT */
 	GATE(CLK_PCLK_MONOTONIC_CNT, "pclk_monotonic_cnt", "div_aclk_mif_133",
-			ENABLE_PCLK_MIF_SECURE_RTC, 0, 0, 0),
+			ENABLE_PCLK_MIF_SECURE_MONOTONIC_CNT, 0, 0, 0),
 
 	/* ENABLE_PCLK_MIF_SECURE_RTC */
 	GATE(CLK_PCLK_RTC, "pclk_rtc", "div_aclk_mif_133",