瀏覽代碼

thermal: qoriq: Simplify the 'site' variable assignment

There is no need to assign zero to the variable 'site' and then
perform a compound bitwise OR operation afterwards.

Make it simpler by assigning the final 'site' value directly.

Signed-off-by: Fabio Estevam <fabio.estevam@nxp.com>
Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Fabio Estevam 7 年之前
父節點
當前提交
1a893a5a19
共有 1 個文件被更改,包括 2 次插入2 次删除
  1. 2 2
      drivers/thermal/qoriq_thermal.c

+ 2 - 2
drivers/thermal/qoriq_thermal.c

@@ -197,7 +197,7 @@ static int qoriq_tmu_probe(struct platform_device *pdev)
 	int ret;
 	struct qoriq_tmu_data *data;
 	struct device_node *np = pdev->dev.of_node;
-	u32 site = 0;
+	u32 site;
 
 	if (!np) {
 		dev_err(&pdev->dev, "Device OF-Node is NULL");
@@ -244,7 +244,7 @@ static int qoriq_tmu_probe(struct platform_device *pdev)
 	}
 
 	/* Enable monitoring */
-	site |= 0x1 << (15 - data->sensor_id);
+	site = 0x1 << (15 - data->sensor_id);
 	tmu_write(data, site | TMR_ME | TMR_ALPF, &data->regs->tmr);
 
 	return 0;