pata_it8213: fix wrong PIO timings being programmed

* do not clear PIO timings for master when programming slave
* program new PIO timings in the correct register nibble

Both changes should be safe as this is how we have been doing
things in IDE it8213 host driver for years.

Signed-off-by: Bartlomiej Zolnierkiewicz <bzolnier@gmail.com>
Signed-off-by: Jeff Garzik <jgarzik@redhat.com>
Bartlomiej Zolnierkiewicz 16 년 전
부모
커밋
088ccb53a3
1개의 변경된 파일2개의 추가작업 그리고 2개의 파일을 삭제
  1. 2 2
      drivers/ata/pata_it8213.c

+ 2 - 2
drivers/ata/pata_it8213.c

@@ -112,13 +112,13 @@ static void it8213_set_piomode (struct ata_port *ap, struct ata_device *adev)
 	} else {
 		u8 slave_data;
 
-		idetm_data &= 0xCC0F;
+		idetm_data &= 0xFF0F;
 		idetm_data |= (control << 4);
 
 		/* Slave timing in separate register */
 		pci_read_config_byte(dev, 0x44, &slave_data);
 		slave_data &= 0xF0;
-		slave_data |= ((timings[pio][0] << 2) | timings[pio][1]) << 4;
+		slave_data |= (timings[pio][0] << 2) | timings[pio][1];
 		pci_write_config_byte(dev, 0x44, slave_data);
 	}