@@ -9,6 +9,7 @@ Required properties:
|
|
|
Examples with soctypes are:
|
|
|
- "renesas,r8a7795-thermal" (R-Car H3)
|
|
|
- "renesas,r8a7796-thermal" (R-Car M3-W)
|
|
|
+ - "renesas,r8a77965-thermal" (R-Car M3-N)
|
|
|
- reg : Address ranges of the thermal registers. Each sensor
|
|
|
needs one address range. Sorting must be done in
|
|
|
increasing order according to datasheet, i.e.
|
|
@@ -18,7 +19,7 @@ Required properties:
|
|
|
|
|
|
Optional properties:
|
|
|
|
|
|
-- interrupts : interrupts routed to the TSC (3 for H3 and M3-W)
|
|
|
+- interrupts : interrupts routed to the TSC (3 for H3, M3-W and M3-N)
|
|
|
- power-domain : Must contain a reference to the power domain. This
|
|
|
property is mandatory if the thermal sensor instance
|
|
|
is part of a controllable power domain.
|