@@ -1,27 +1,71 @@
|
|
-pwm regulator bindings
|
|
|
|
|
|
+Bindings for the Generic PWM Regulator
|
|
|
|
+======================================
|
|
|
|
+
|
|
|
|
+Currently supports 2 modes of operation:
|
|
|
|
+
|
|
|
|
+voltage-table: When in this mode, a voltage table (See below) of
|
|
|
|
+ predefined voltage <=> duty-cycle values must be
|
|
|
|
+ provided via DT. Limitations are that the regulator can
|
|
|
|
+ only operate at the voltages supplied in the table.
|
|
|
|
+ Intermediary duty-cycle values which would normally
|
|
|
|
+ allow finer grained voltage selection are ignored and
|
|
|
|
+ rendered useless. Although more control is given to
|
|
|
|
+ the user if the assumptions made in continuous-voltage
|
|
|
|
+ mode do not reign true.
|
|
|
|
+
|
|
|
|
+continuous-voltage: This mode uses the regulator's maximum and minimum
|
|
|
|
+ supplied voltages specified in the
|
|
|
|
+ regulator-{min,max}-microvolt properties to calculate
|
|
|
|
+ appropriate duty-cycle values. This allows for a much
|
|
|
|
+ more fine grained solution when compared with
|
|
|
|
+ voltage-table mode above. This solution does make an
|
|
|
|
+ assumption that a %50 duty-cycle value will cause the
|
|
|
|
+ regulator voltage to run at half way between the
|
|
|
|
+ supplied max_uV and min_uV values.
|
|
|
|
|
|
Required properties:
|
|
Required properties:
|
|
-- compatible: Should be "pwm-regulator"
|
|
|
|
-- pwms: OF device-tree PWM specification (see PWM binding pwm.txt)
|
|
|
|
-- voltage-table: voltage and duty table, include 2 members in each set of
|
|
|
|
- brackets, first one is voltage(unit: uv), the next is duty(unit: percent)
|
|
|
|
|
|
+--------------------
|
|
|
|
+- compatible: Should be "pwm-regulator"
|
|
|
|
+
|
|
|
|
+- pwms: PWM specification (See: ../pwm/pwm.txt)
|
|
|
|
+
|
|
|
|
+One of these must be provided:
|
|
|
|
+- voltage-table: Voltage and Duty-Cycle table consisting of 2 cells
|
|
|
|
+ First cell is voltage in microvolts (uV)
|
|
|
|
+ Second cell is duty-cycle in percent (%)
|
|
|
|
+
|
|
|
|
+- max-duty-cycle: Maximum Duty-Cycle value -- this will normally be
|
|
|
|
+ 255 (0xff) for an 8 bit PWM device
|
|
|
|
|
|
-Any property defined as part of the core regulator binding defined in
|
|
|
|
-regulator.txt can also be used.
|
|
|
|
|
|
+If both are provided, the current default is voltage-table mode.
|
|
|
|
|
|
-Example:
|
|
|
|
|
|
+Any property defined as part of the core regulator binding can also be used.
|
|
|
|
+(See: ../regulator/regulator.txt)
|
|
|
|
+
|
|
|
|
+Continuous Voltage Example:
|
|
pwm_regulator {
|
|
pwm_regulator {
|
|
compatible = "pwm-regulator;
|
|
compatible = "pwm-regulator;
|
|
pwms = <&pwm1 0 8448 0>;
|
|
pwms = <&pwm1 0 8448 0>;
|
|
|
|
+ regulator-min-microvolt = <1016000>;
|
|
|
|
+ regulator-max-microvolt = <1114000>;
|
|
|
|
+ regulator-name = "vdd_logic";
|
|
|
|
+
|
|
|
|
+ max-duty-cycle = <255>; /* 8bit PWM */
|
|
|
|
+ };
|
|
|
|
|
|
|
|
+Voltage Table Example:
|
|
|
|
+ pwm_regulator {
|
|
|
|
+ compatible = "pwm-regulator;
|
|
|
|
+ pwms = <&pwm1 0 8448 0>;
|
|
|
|
+ regulator-min-microvolt = <1016000>;
|
|
|
|
+ regulator-max-microvolt = <1114000>;
|
|
|
|
+ regulator-name = "vdd_logic";
|
|
|
|
+
|
|
|
|
+ /* Voltage Duty-Cycle */
|
|
voltage-table = <1114000 0>,
|
|
voltage-table = <1114000 0>,
|
|
<1095000 10>,
|
|
<1095000 10>,
|
|
<1076000 20>,
|
|
<1076000 20>,
|
|
<1056000 30>,
|
|
<1056000 30>,
|
|
<1036000 40>,
|
|
<1036000 40>,
|
|
<1016000 50>;
|
|
<1016000 50>;
|
|
-
|
|
|
|
- regulator-min-microvolt = <1016000>;
|
|
|
|
- regulator-max-microvolt = <1114000>;
|
|
|
|
- regulator-name = "vdd_logic";
|
|
|
|
};
|
|
};
|