NEWS 20 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492
  1. libmodbus 3.1.3 (2016-05-11)
  2. ============================
  3. - New bswap macros for Max OSX by Jakob Bysewski.
  4. - Fix "wildcard address" in TCP IPv6 by Shoichi Sakane.
  5. - Introduce offsets in modbus mappings with modbus_mapping_new_start_address.
  6. Thanks to Michael Heimpold and Stéphane Raimbault.
  7. - Fix address range in random-test-client.
  8. Thanks to Martin Galvan.
  9. - Add an option to disable tests compilation by Yegor Yefremov.
  10. - Define MSG_DONTWAIT to MSG_NONBLOCK on AIX (#294).
  11. Thanks to Fabrice Cantos.
  12. - Fix building when byteswap.h is not defined by Tomasz Mon.
  13. - Add some more macros for data manipulation and documentation.
  14. - Remove duplicate install of modbus.h (closes #290).
  15. Thanks to Daniel Sutcliffe.
  16. - Move MIGRATION and README.md to dist_doc_DATA target.
  17. - Change order of few functions in modbus RTU code.
  18. - Add entries for modbus_rtu_[get|set]_delay in documentation index.
  19. - Implemented runtime configurable RTS delay by Jimmy Bergström.
  20. - Add an entry in libmodbus index page for modbus_rtu_set_custom_rts.
  21. - Add support for user defined RTS toggle function by Jimmy
  22. Bergström.
  23. - Added ILLEGAL_DATA_ADDRESS tests for modbus_write_register[|s].
  24. Thanks to Andrey Skvortsov.
  25. - Update documentation of modbus_rtu_set_rts
  26. - Fix rts signal switch time by Hiromasa Ihara.
  27. - Improve new_rtu and set_slave documentation (related to #276).
  28. - Fix late check of ctx in modbus_reply[|_exception] (closes #269).
  29. - Wait the server for 1 second before running tests (help Travis).
  30. - A libmodbus context isn't thread safe and won't be (closes #246).
  31. - Fix buffer overflow in modbus_mask_write_register (#265).
  32. - Minor adjustments to README about AsciiDoc.
  33. - Export MODBUS_MAX_ADU_LENGTH and documentation (ref #241).
  34. - Explicit check against Modbus broadcast address.
  35. - Do not reply on broadcast requests (fixes #153). Thanks to Michael.
  36. - Add Travis support.
  37. - Run unit tests with standard: make check (closes #205, closes #238).
  38. This patch has been developed by Andrey Skvortsov, Michael Heimpold
  39. and Stéphane Raimbault.
  40. - modbus_send_raw_request: limit request length (fixes #207).
  41. Thanks to Hanno Neuer for spotting this security flaw.
  42. - Add new contributors to AUTHORS
  43. - Introduce SPDX license identifiers. Thanks to Michael Heimpold.
  44. libmodbus 3.1.2 (2015-02-13)
  45. ============================
  46. If you still want to listen any addresses in your TCP IPv4 server, you must now
  47. set the IP address to NULL in modbus_new_tcp before listening. Now,
  48. modbus_tcp_listen only listen the IP address set in the Modbus context (see
  49. documentation).
  50. This release introduces API changes on modbus_get_byte_timeout,
  51. modbus_get_response_timeout, modbus_set_byte_timeout,
  52. modbus_set_response_timeout to ease writing of language bindings.
  53. - Rewrite documentation building system
  54. - Fix timeouts in unit tests
  55. - Don't flush on illegal address errors in single write functions
  56. - Fix compilation on compilers not supporting c99 mode.
  57. Thanks to Michael Heimpold.
  58. - Update license for the tests in Debian packaging (#221)
  59. - Move check of device earlier to avoid a free call
  60. - Unit test for baud rate check and error message.
  61. - Fix crash modbus_new_rtu when baud is 0.
  62. Thank you to Daniel Schürmann.
  63. - Removed function prototype without implementation
  64. Thank you Andrej Skvortzov.
  65. - Switch test programs to a BSD license
  66. - Fix remote buffer overflow vulnerability on write requests
  67. - Avoid twice connect() in source code (closes #194)
  68. - Fix compilation with MinGW (GCC 4.8.1) under Win7 (closes #163)
  69. Thank you MarjanTomas and SwissKnife.
  70. - Fix TCP IPv4 modbus_connect() on win32 (closes #100 and #165)
  71. Thank you Petr Gladkiy and Marjan Tomas.
  72. - Fix 24a05ebd3c0 - win32: init of modbus_tcp_pi_listen (#187)
  73. - INADDR_* macros are defined in host byte order
  74. - Filter of IP addresses in IPv4 server (closes #190)
  75. - Allow to listen any hosts in IPv6 (closes #32)
  76. - Define and public export of MODBUS_MAX_PDU_LENGTH (closes #167)
  77. - Truncate data from response in report_slave_id to new max arg (closes #167)
  78. - Fix response timeout modification on connect (closes #80)
  79. - New API to set/get response and byte timeouts.
  80. New unit tests and updated documentation.
  81. - Export Modbus function codes supported by libmodbus
  82. - Fix bandwidth-server-one (closes #152)
  83. - Check debug flag in RTU code
  84. - Remove warnings caused by shadowed 'index' variable.
  85. Thanks to Åke Forslund.
  86. - Use accept4 in TCP PI if available
  87. - Add documentation for tcp[_pi]_accept (closes #31)
  88. - Fix mistake in modbus_tcp_listen documentation
  89. - Add documentation for modbus_tcp_pi_listen
  90. - Fix for MinGW and Windows (#144, #169, #175, #180, #181, #187)
  91. Thanks to Marjan Tomas.
  92. - Many other fixes (#134, #157, #158, #183, #184) and improvements.
  93. libmodbus 3.1.1 (2013-10-06)
  94. ============================
  95. More robust to exploits, more compliant and better handling of connect/close
  96. sequences. Windows support still broken.
  97. - New unit tests
  98. - Fix remote buffer overflow vulnerability (closes #25, #105)
  99. - Explain how to define response timeouts when many RTU slaves
  100. - Fix receiving of incorrect queries in write_single and mask_write_register
  101. Thanks to James Nutaro.
  102. - Check return value of autoreconf.
  103. Thanks to Lauri Nurmi
  104. - Constant for broacast and test ordering
  105. - Fix the fix of device string check
  106. - Various changes to try to improve *broken* Windows support
  107. - Try to fix MinGW compilation
  108. - Portable use of bswap_32
  109. - Improve support of MacOS X
  110. - Fix socket value on init/close
  111. - Returns -1 on invalid mode in modbus_rtu_set_rts
  112. - Protect all public functions against invalid context
  113. - Sleep for delay of response timeout before reconnect (closes #77).
  114. Thanks to Karl Palsson.
  115. - Baud rate until 4,000,000 (POSIX), 1,000,000 (Windows) (closes #93)
  116. - New modbus_get|set_float_dcba to get|set float in inversed byte order
  117. - Remove unsupported -Wtype-limits for GCC < 4.3.5 (closes #109)
  118. - Enable out-of-source build. Thanks to Yegor Yefremov.
  119. - Fix alignment problem on ARMv5 platform
  120. - Improvement to Debian package. Thanks to Alexander Klauer.
  121. - Improve support of VS 2005. Thanks to Petr Gladkiy.
  122. - Add documentation for modbus_mask_write_register (closes #91).
  123. Thanks to Martijn de Gouw.
  124. - Avoid C99 declaration in win32 section code (closes #92).
  125. Thanks to oldfaber and endrelovas.
  126. - Add a windows scripting host configure file.
  127. Thanks to oldfaber and Stéphane Raimbault.
  128. - Fix typo in modbus_strerror documentation. Thanks to Mirko Rajkovaca.
  129. - Rename reserved C++ keywords of modbus_mask_write_register.
  130. Thanks Tobias Doerffel.
  131. - Another quick workaround for deficient OS (closes #63)
  132. - Add support for Mask Write Register
  133. - Fix missing close on socket in random-test-server.
  134. Thanks to Damian Zieliński.
  135. - Use nonblocking sockets on Win32 and OS X/iOS too.
  136. Thanks to Julian Raschke.
  137. - Fix all compilations warnings spotted by new compilation flags
  138. - Major update of build system
  139. - Calculate RTS activation time by send length
  140. - Dynamic memory allocation of device name (closes #11)
  141. - Add unit tests for modbus_mapping_new
  142. - Add Visual Studio 2008 project files by oldfaber
  143. - Fix missing argument in synopsis section of modbus_rtu_set_serial_mode
  144. - Fix wrong constant names to create version number
  145. - More compilation fixes for Windows by oldfaber.
  146. - Fix wrong constant names to create version number.
  147. Thanks to Denis Davydov.
  148. libmodbus 3.1.0 (2012-06-22)
  149. ============================
  150. Major changes to handle many slaves in RTU mode, non blocking connections and
  151. RTS flow control.
  152. - Fixes for Microsoft Visual C++ compiler
  153. - Fixes for Windows. Thanks to oldfaber
  154. - Return value of _modbus_tcp_pi_connect() on failure (closes #61)
  155. - Avoid ioctl call on non-RS485 ports. Thanks to Michael Haberler
  156. - Display node and service in PI and port in IPv4 at connection
  157. - Return -1 on getaddrinfo error and print error in debug mode
  158. - More robust way to establish the connection in non blocking mode
  159. - TCP - Socket in non blocking mode by default. Thanks to Thomas Stalder
  160. - Apply CLOEXEC flag for TCP protocol independent too (IPv6)
  161. - New RTU receive() to ignore confirmation from other slaves (closes #18)
  162. - Move RTU filtering in CRC check to avoid useless call to modbus_reply
  163. - Unique transaction identifier by TCP connection
  164. - Use accept4 with SOCK_CLOEXEC when available (Linux)
  165. - Open fd and socket with the CLOEXEC flag when available
  166. - Exception response on report slave ID wasn't detected (closes #27)
  167. - Provides a way to disable the byte timeout (Alex Stapleton)
  168. - Added slave ID check for response messages (Alex Stapleton)
  169. - RTS flow control with modbus_rtu_set_rts and modbus_rtu_get_rts
  170. functions by Torello Querci <tquerci@gmail.com> and Stéphane Raimbault.
  171. libmodbus 3.0.4 (2012-05-08)
  172. ============================
  173. - autogen.sh creates symlinks instead of copies
  174. - Add missing m4 directory (closes #103)
  175. - Fix alignment problem on ARMv5 platform
  176. Thanks to Alexander Dahl
  177. - Remove useless test on error_recovery argument
  178. Thanks to Carlos Tangerino
  179. libmodbus 3.0.3 (2012-05-25)
  180. ============================
  181. - Fix another Visual C++ 2008/2010 deficiency (closes #53)
  182. - Add -lsocket to compile on QNX
  183. - Fix TCP PI init under Windows.
  184. Thanks to oldfaber.
  185. - Fix a missing free in random-test-client
  186. Thanks again to Stefan Finzel.
  187. - Fix OMG bug in modbus_mapping_free not freeing memory.
  188. Thanks to Stefan Finzel for the bug report.
  189. - Fix semicolon typo and unistd.h include under Windows.
  190. Thanks to Andrew Kravchuk.
  191. libmodbus 3.0.2 (2012-01-16)
  192. ============================
  193. - Update Debian package
  194. - Documentation fixes and additions
  195. - Add missing C++ macros in public headers.
  196. Thanks to Bernhard Agthe.
  197. - Protects modbus_mapping_free against NULL argument.
  198. Thanks to Andrea Mattia
  199. - Fix check on file doc/libmodbus.7 in acinclude.m4 (closes #28)
  200. - Close file descriptor when the settings don't apply in RTU.
  201. Original patch provided by Thomas Stalder.
  202. - unit-test.h is now generated to avoid config.h dependency.
  203. - Request for Windows Sockets specification version 2.2 instead of 2.0
  204. Thanks to Pavel Mazniker for the report.
  205. libmodbus 3.0.1 (2011-07-18)
  206. ============================
  207. - Avoid useless serial_mode integer when TIOCSRS485 isn't supported
  208. - Fix compilation failure on Windows (RS485 support) by Tobias Doerffel
  209. <tobias.doerffel@gmail.com>
  210. - Properly check TIOCSRS485 define by Matthijs Kool
  211. - Rename package to libmodbus5 to fix lintian warning
  212. libmodbus 3.0.0 (2011-07-11)
  213. ============================
  214. - Revert libmodbus licence from LGPLv3 to LGPLv2.1 to avoid
  215. incompatibility with GPLv2 program. This change has been approved
  216. by Tobias Doerffel, Florian octo Forster and Hannu Vuolasaho.
  217. - Enable RS485 support only when available
  218. - Export modbus_set/get_serial_mode functions on all platforms
  219. - API change for read/write multiple registers function:
  220. * modbus_read_and_write_registers -> modbus_write_and_read_registers
  221. The function name was confusing because the write operation is performed
  222. before the read. Take care to swap the arguments in the migration process.
  223. - Documentation of modbus_write_and_read_registers, modbus_mapping_new/free,
  224. report_slave_id. modbus_get_byte_from_bits, modbus_set_bits_from_byte(s),
  225. modbus_[gs]et_float, modbus_reply and modbus_reply_exception.
  226. - Enhanced report slave ID
  227. - New RPM spec file to package documentation and development files
  228. libmodbus 2.9.4 (2011-06-05)
  229. ============================
  230. - IPv6 support
  231. Make the TCP implementation "protocol independent" by Florian Forster
  232. and Stéphane Raimbault.
  233. - Fix compilation on Windows 7 (x64) with MinGW/MSYS and GCC 4.5
  234. Reported by Patsy Kaye.
  235. - Documentation of libmodbus functions with AsciiDoc (man and HTML) by Stéphane
  236. Raimbault
  237. - Avoid an iteration in flush function
  238. - New functions to send and receive raw requests (modbus_send_raw_request,
  239. modbus_receive_confirmation)
  240. - Fix flush function of TCP backend on Windows
  241. - API changes for server/slave:
  242. * modbus_receive doesn't take socket/fd argument anymore
  243. * new function modbus_set_socket to set socket/fd
  244. - API changes for timeout functions:
  245. * modbus_get_timeout_begin -> modbus_get_response_timeout
  246. * modbus_set_timeout_begin -> modbus_set_response_timeout
  247. * modbus_get_timeout_end -> modbus_get_byte_timeout
  248. * modbus_set_timeout_end -> modbus_set_byte_timeout
  249. - Fix longstanding limitation of server to wait forever
  250. - New functions modbus_set/get_serial_mode by Manfred Gruber and Stéphane
  251. Raimbault for RS485 communications
  252. - Improved recovery mode (see modbus_set_error_recovery documentation) for
  253. data link and protocol errors.
  254. - Fix compilation issue with Microsoft Visual Studio 2008.
  255. Reported by Allan Cornet.
  256. libmodbus 2.9.3 (2011-01-14)
  257. ============================
  258. - Major rewriting of the message reading (no more timeouts on exception)
  259. by Stéphane Raimbault
  260. - New function to reply to an indication with an exception message
  261. modbus_reply_exception()
  262. - New function modbus_get_header_length(modbus_t *ctx)
  263. - New functions to manipulate data:
  264. * MODBUS_GET_INT32_FROM_INT16
  265. * MODBUS_GET_INT16_FROM_INT8
  266. * MODBUS_SET_INT16_TO_INT8
  267. - Fix GH-2. Read/write were swapped in _FC_READ_AND_WRITE_REGISTERS
  268. - Install an ignore handler for SIGPIPE on *BSD
  269. Original patch by Jason Oster.
  270. - Fix closing of Win32 socket.
  271. Reported by Petr Parýzek.
  272. - Fix unit identifier not copied by the TCP server.
  273. Reported by Antti Manninen.
  274. - Fix missing modbus_flush() in unit tests
  275. - Fixes for OpenBSD by Barry Grumbine and Jason Oster
  276. libmodbus 2.9.2 (2010-12-05)
  277. ============================
  278. - Win32 support by Tobias Doerffel
  279. - Split source code around RTU and TCP (backends)
  280. - Rename modbus_[listen|accept] to modbus_tcp_[listen|accept]
  281. - Remove slave argument from modbus_new_rtu()
  282. - Check received function code
  283. - Fix segfault in bandwidth-server-many-up on inet_ntoa() call
  284. - Fix unit test of report slave ID in RTU
  285. - Fix GH-3. Remove inclusion of config.h in modbus.h
  286. - Correctly detect if we are cross-compiling for win32 by Kirill Smelkov.
  287. - Fix setting of the broadcast address
  288. libmodbus 2.9.1 (2010-08-16)
  289. ============================
  290. - Brand new API (see MIGRATION notes)!
  291. - Remove the internal function set_message_length_tcp
  292. - Restore slave ID (server ID) argument in functions
  293. - Error conventions of POSIX systems and error recover
  294. - Parity setting is now a single char ('N', 'E' or 'O')
  295. - Report slave ID server side
  296. - OpenBSD support by Anibal Limón.
  297. - New read and write registers function by Hannu Vuolasaho.
  298. - Versioning infrastructure
  299. Inspired by the Clutter project and the work done by Florian Forster.
  300. - Fix the broadcast constant (255 -> 0)
  301. Reported by David Olivari.
  302. - Fix #463299 - New functions to define the timeouts of begin and end of trame
  303. Original patch by Sisyph (eric-paul).
  304. - Fix #591142 - Slave id check should be disabled in TCP connection
  305. Reported by aladdinwu.
  306. libmodbus 2.1.0 (2010-03-24)
  307. ============================
  308. - New API to read and write float values by Stéphane Raimbault and Florian
  309. Forster.
  310. - New API for slave server (see MIGRATION)
  311. - New slave server able to handle multiple connections
  312. - Slave only replies to broadcast queries or queries with its slave ID
  313. - Improved Modbus protocol conformance
  314. - modbus_param_t is smaller (2 int removed)
  315. - Better error management and SIGPIPE signal is blocked
  316. - Faster
  317. - Fix #333455 - Cygwin IPTOS_LOWDELAY not supported on cygwin
  318. Reported by Jeff Laughlin and Yishin Li.
  319. - Fix #375926 - modbus.c:164: error: `MSG_DONTWAIT' undeclared
  320. Reported and tested by Yishin Li.
  321. - Fix #378981 - CRC error on RTU response doesn't return negative value
  322. Reported by Henrik Munktell.
  323. - Fix report slave ID request
  324. Patch (bzr) provided by Paul Fertser.
  325. - Fix #425604 - Conditional jump or move depends on uninitialised value(s)
  326. Occurs on first occurence of slave timeout.
  327. Reported by Henrik Munktell.
  328. - Fix #457200 - FreeBSD support
  329. Patch provided by Norbert Koch.
  330. Other changes:
  331. - The code is now published and developed on
  332. http://github.com/stephane/libmodbus
  333. - Waf support has been removed
  334. libmodbus 2.0.3 (2009-03-22)
  335. ============================
  336. - Fix CRC error when a slave RTU send a response.
  337. Thanks to Justin Carroll to have reported and tested my patch.
  338. - Remove an assignment in compute_response_length()
  339. - Remove duplicate counter in read_io_status()
  340. - Fix #274511 reported by 'Kylesch'
  341. Invalid error check in modbus_init_listen_tcp
  342. libmodbus 2.0.2 (2008-08-10)
  343. ============================
  344. - Fix a bug reported by email by Davide Pippa
  345. The function modbus_receive must check the number of values
  346. indicated in the response accordingly to the query.
  347. - Fix #241006 reported by Jesus Hernandez Tapia
  348. modbus_check_response() crashes on an invalid exception code
  349. - Reduce the number of function calls (read_reg_response and
  350. preset_response have been removed)
  351. - Add a new unit test for bad response
  352. - Catch the timeout even if the length is equal to a exception trame
  353. - Test only msg_length_computed on change
  354. - Many comments and cleanups
  355. libmodbus 2.0.1 (2008-07-02)
  356. ============================
  357. - Include libmodbus.spec in the tarball
  358. - Fix #241006 reported by Jesus Hernandez Tapia
  359. modbus_check_response() crashes on an invalid exception code
  360. libmodbus 2.0.0 (2008-05-18)
  361. ============================
  362. - Slave API
  363. https://blueprints.launchpad.net/libmodbus/+spec/slave-api
  364. - No more glib dependency
  365. https://blueprints.launchpad.net/libmodbus/+spec/glib-dependency
  366. - Unit testing and many test programs
  367. - Waf build support
  368. https://blueprints.launchpad.net/libmodbus/+spec/waf-support
  369. - MacOS X support by Matthew Butch
  370. https://blueprints.launchpad.net/libmodbus/+spec/macosx-support
  371. - Unit testing (unit-test-slave and unit-test-master)
  372. - Port number is now defined at initialisation by Dirk Reusch
  373. - Better memory management (uint8_t *data and packing of
  374. modbus_param_t)
  375. - Better error management
  376. - Declare many static functions and const arrays
  377. - Enhance an integer division
  378. - The GNU licences LGPL and GPL are in version 3
  379. - Debian and RPM packages (#224496)
  380. - Many cleanups
  381. - Fix #159443 reported by Stefan Bisanz
  382. Index of incoming data in force multiple coils function
  383. - Fix #161989 reported by Konstantinos Togias
  384. Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
  385. fit to modbus_param_t -> device char[11] var.
  386. - Fix #188189 reported by Chris Hellyar
  387. Compute_response_size() no entry for read_input_status()
  388. - Fix #191039 reported by Todd Denniston
  389. modbus.h is not installed at prefix.
  390. - Fix #211460 reported by Todd Denniston
  391. With TCP, automatic reconnect on error may not be desired.
  392. - Fix #224485 reported by Todd Denniston
  393. libmodbus does not link with c++ code.
  394. - Fix #224496 reported by Todd Denniston
  395. It is easier to install on rpm based systems with a spec file.
  396. libmodbus 1.2.5 (2008-05-18)
  397. ============================
  398. - Fix #224485 reported by Todd Denniston
  399. libmodbus does not link with c++ code.
  400. libmodbus 1.2.4 (2008-03-14)
  401. ============================
  402. - Fix #191039 reported by Todd Denniston
  403. modbus.h is not installed at prefix.
  404. libmodbus 1.2.3 (2008-02-03)
  405. ============================
  406. - Fix #188189 reported by Chris Hellyar
  407. Compute_response_size() no entry for read_input_status()
  408. - Fix #181887 reported by Jesus Hernandez Tapia.
  409. Slave address in build_request_packet_tcp() is hardcoded as 0xFF.
  410. libmodbus 1.2.2 (2007-11-12)
  411. ============================
  412. - Fix #161989 reported by Konstantinos Togias
  413. Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
  414. fit to modbus_param_t -> device char[11] var.
  415. - Structure is also bit better 'packed' to conserve memory (see the
  416. trunk for a real enhancement).
  417. libmodbus 1.2.1 (2007-11-02)
  418. ============================
  419. - Fix #159443 reported by Stefan Bisanz
  420. Index of incoming data in force multiple coils function
  421. - Deleted useless code in check_crc16()
  422. - Untabify source code
  423. - Changed author's email to Stéphane Raimbault
  424. libmodbus 1.2.0 (2007-05-10)
  425. ============================
  426. - FIX Compilation GCC-4.0
  427. - Project name in autogen.sh