NEWS 9.5 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261
  1. libmodbus 2.9.5 (2011-07-XX)
  2. ============================
  3. - Revert libmodbus licence from LGPLv3 to LGPLv2.1 to avoid
  4. incompatibility with GPLv2 program. This change has been approved
  5. by Tobias Doerffel, Florian octo Forster and Hannu Vuolasaho.
  6. - Enable RS485 support only when available
  7. - Export modbus_set/get_serial_mode functions on all platforms
  8. - API change for read/write multiple registers function:
  9. * modbus_read_and_write_registers -> modbus_write_and_read_registers
  10. The function name was confusing because the write operation is performed
  11. before the read. Take care to swap the arguments in the migration process.
  12. - Documentation of modbus_write_and_read_registers, modbus_mapping_new/free,
  13. report_slave_id. modbus_get_byte_from_bits, modbus_set_bits_from_byte(s),
  14. modbus_[gs]et_float, modbus_reply and modbus_reply_exception.
  15. - Enhanced report slave ID
  16. - New RPM spec file to package documentation and development files
  17. libmodbus 2.9.4 (2011-06-05)
  18. ============================
  19. - IPv6 support
  20. Make the TCP implementation "protocol independent" by Florian Forster
  21. and Stéphane Raimbault.
  22. - Fix compilation on Windows 7 (x64) with MinGW/MSYS and GCC 4.5
  23. Reported by Patsy Kaye.
  24. - Documentation of libmodbus functions with AsciiDoc (man and HTML) by Stéphane
  25. Raimbault
  26. - Avoid an iteration in flush function
  27. - New functions to send and receive raw requests (modbus_send_raw_request,
  28. modbus_receive_confirmation)
  29. - Fix flush function of TCP backend on Windows
  30. - API changes for server/slave:
  31. * modbus_receive doesn't take socket/fd argument anymore
  32. * new function modbus_set_socket to set socket/fd
  33. - API changes for timeout functions:
  34. * modbus_get_timeout_begin -> modbus_get_response_timeout
  35. * modbus_set_timeout_begin -> modbus_set_response_timeout
  36. * modbus_get_timeout_end -> modbus_get_byte_timeout
  37. * modbus_set_timeout_end -> modbus_set_byte_timeout
  38. - Fix longstanding limitation of server to wait forever
  39. - New functions modbus_set/get_serial_mode by Manfred Gruber and Stéphane
  40. Raimbault for RS485 communications
  41. - Improved recovery mode (see modbus_set_error_recovery documentation) for
  42. data link and protocol errors.
  43. - Fix compilation issue with Microsoft Visual Studio 2008.
  44. Reported by Allan Cornet.
  45. libmodbus 2.9.3 (2011-01-14)
  46. ============================
  47. - Major rewriting of the message reading (no more timeouts on exception)
  48. by Stéphane Raimbault
  49. - New function to reply to an indication with an exception message
  50. modbus_reply_exception()
  51. - New function modbus_get_header_length(modbus_t *ctx)
  52. - New functions to manipulate data:
  53. * MODBUS_GET_INT32_FROM_INT16
  54. * MODBUS_GET_INT16_FROM_INT8
  55. * MODBUS_SET_INT16_TO_INT8
  56. - Fix GH-2. Read/write were swapped in _FC_READ_AND_WRITE_REGISTERS
  57. - Install an ignore handler for SIGPIPE on *BSD
  58. Original patch by Jason Oster.
  59. - Fix closing of Win32 socket.
  60. Reported by Petr Parýzek.
  61. - Fix unit identifier not copied by the TCP server.
  62. Reported by Antti Manninen.
  63. - Fix missing modbus_flush() in unit tests
  64. - Fixes for OpenBSD by Barry Grumbine and Jason Oster
  65. libmodbus 2.9.2 (2010-12-05)
  66. ============================
  67. - Win32 support by Tobias Doerffel
  68. - Split source code around RTU and TCP (backends)
  69. - Rename modbus_[listen|accept] to modbus_tcp_[listen|accept]
  70. - Remove slave argument from modbus_new_rtu()
  71. - Check received function code
  72. - Fix segfault in bandwidth-server-many-up on inet_ntoa() call
  73. - Fix unit test of report slave ID in RTU
  74. - Fix GH-3. Remove inclusion of config.h in modbus.h
  75. - Correctly detect if we are cross-compiling for win32 by Kirill Smelkov.
  76. - Fix setting of the broadcast address
  77. libmodbus 2.9.1 (2010-08-16)
  78. ============================
  79. - Brand new API (see MIGRATION notes)!
  80. - Remove the internal function set_message_length_tcp
  81. - Restore slave ID (server ID) argument in functions
  82. - Error conventions of POSIX systems and error recover
  83. - Parity setting is now a single char ('N', 'E' or 'O')
  84. - Report slave ID server side
  85. - OpenBSD support by Anibal Limón.
  86. - New read and write registers function by Hannu Vuolasaho.
  87. - Versioning infrastructure
  88. Inspired by the Clutter project and the work done by Florian Forster.
  89. - Fix the broadcast constant (255 -> 0)
  90. Reported by David Olivari.
  91. - Fix #463299 - New functions to define the timeouts of begin and end of trame
  92. Original patch by Sisyph (eric-paul).
  93. - Fix #591142 - Slave id check should be disabled in TCP connection
  94. Reported by aladdinwu.
  95. libmodbus 2.1.0 (2010-03-24)
  96. ============================
  97. - New API to read and write float values by Stéphane Raimbault and Florian
  98. Forster.
  99. - New API for slave server (see MIGRATION)
  100. - New slave server able to handle multiple connections
  101. - Slave only replies to broadcast queries or queries with its slave ID
  102. - Improved Modbus protocol conformance
  103. - modbus_param_t is smaller (2 int removed)
  104. - Better error management and SIGPIPE signal is blocked
  105. - Faster
  106. - Fix #333455 - Cygwin IPTOS_LOWDELAY not supported on cygwin
  107. Reported by Jeff Laughlin and Yishin Li.
  108. - Fix #375926 - modbus.c:164: error: `MSG_DONTWAIT' undeclared
  109. Reported and tested by Yishin Li.
  110. - Fix #378981 - CRC error on RTU response doesn't return negative value
  111. Reported by Henrik Munktell.
  112. - Fix report slave ID request
  113. Patch (bzr) provided by Paul Fertser.
  114. - Fix #425604 - Conditional jump or move depends on uninitialised value(s)
  115. Occurs on first occurence of slave timeout.
  116. Reported by Henrik Munktell.
  117. - Fix #457200 - FreeBSD support
  118. Patch provided by Norbert Koch.
  119. Other changes:
  120. - The code is now published and developed on
  121. http://github.com/stephane/libmodbus
  122. - Waf support has been removed
  123. libmodbus 2.0.3 (2009-03-22)
  124. ============================
  125. - Fix CRC error when a slave RTU send a response.
  126. Thanks to Justin Carroll to have reported and tested my patch.
  127. - Remove an assignment in compute_response_length()
  128. - Remove duplicate counter in read_io_status()
  129. - Fix #274511 reported by 'Kylesch'
  130. Invalid error check in modbus_init_listen_tcp
  131. libmodbus 2.0.2 (2008-08-10)
  132. ============================
  133. - Fix a bug reported by email by Davide Pippa
  134. The function modbus_receive must check the number of values
  135. indicated in the response accordingly to the query.
  136. - Fix #241006 reported by Jesus Hernandez Tapia
  137. modbus_check_response() crashes on an invalid exception code
  138. - Reduce the number of function calls (read_reg_response and
  139. preset_response have been removed)
  140. - Add a new unit test for bad response
  141. - Catch the timeout even if the length is equal to a exception trame
  142. - Test only msg_length_computed on change
  143. - Many comments and cleanups
  144. libmodbus 2.0.1 (2008-07-02)
  145. ============================
  146. - Include libmodbus.spec in the tarball
  147. - Fix #241006 reported by Jesus Hernandez Tapia
  148. modbus_check_response() crashes on an invalid exception code
  149. libmodbus 2.0.0 (2008-05-18)
  150. ============================
  151. - Slave API
  152. https://blueprints.launchpad.net/libmodbus/+spec/slave-api
  153. - No more glib dependency
  154. https://blueprints.launchpad.net/libmodbus/+spec/glib-dependency
  155. - Unit testing and many test programs
  156. - Waf build support
  157. https://blueprints.launchpad.net/libmodbus/+spec/waf-support
  158. - MacOS X support by Matthew Butch
  159. https://blueprints.launchpad.net/libmodbus/+spec/macosx-support
  160. - Unit testing (unit-test-slave and unit-test-master)
  161. - Port number is now defined at initialisation by Dirk Reusch
  162. - Better memory management (uint8_t *data and packing of
  163. modbus_param_t)
  164. - Better error management
  165. - Declare many static functions and const arrays
  166. - Enhance an integer division
  167. - The GNU licences LGPL and GPL are in version 3
  168. - Debian and RPM packages (#224496)
  169. - Many cleanups
  170. - Fix #159443 reported by Stefan Bisanz
  171. Index of incoming data in force multiple coils function
  172. - Fix #161989 reported by Konstantinos Togias
  173. Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
  174. fit to modbus_param_t -> device char[11] var.
  175. - Fix #188189 reported by Chris Hellyar
  176. Compute_response_size() no entry for read_input_status()
  177. - Fix #191039 reported by Todd Denniston
  178. modbus.h is not installed at prefix.
  179. - Fix #211460 reported by Todd Denniston
  180. With TCP, automatic reconnect on error may not be desired.
  181. - Fix #224485 reported by Todd Denniston
  182. libmodbus does not link with c++ code.
  183. - Fix #224496 reported by Todd Denniston
  184. It is easier to install on rpm based systems with a spec file.
  185. libmodbus 1.2.5 (2008-05-18)
  186. ============================
  187. - Fix #224485 reported by Todd Denniston
  188. libmodbus does not link with c++ code.
  189. libmodbus 1.2.4 (2008-03-14)
  190. ============================
  191. - Fix #191039 reported by Todd Denniston
  192. modbus.h is not installed at prefix.
  193. libmodbus 1.2.3 (2008-02-03)
  194. ============================
  195. - Fix #188189 reported by Chris Hellyar
  196. Compute_response_size() no entry for read_input_status()
  197. - Fix #181887 reported by Jesus Hernandez Tapia.
  198. Slave address in build_request_packet_tcp() is hardcoded as 0xFF.
  199. libmodbus 1.2.2 (2007-11-12)
  200. ============================
  201. - Fix #161989 reported by Konstantinos Togias
  202. Serial device paths more than 10 chars long (eg. /dev/ttyUSB0) don't
  203. fit to modbus_param_t -> device char[11] var.
  204. - Structure is also bit better 'packed' to conserve memory (see the
  205. trunk for a real enhancement).
  206. libmodbus 1.2.1 (2007-11-02)
  207. ============================
  208. - Fix #159443 reported by Stefan Bisanz
  209. Index of incoming data in force multiple coils function
  210. - Deleted useless code in check_crc16()
  211. - Untabify source code
  212. - Changed author's email to Stéphane Raimbault
  213. libmodbus 1.2.0 (2007-05-10)
  214. ============================
  215. - FIX Compilation GCC-4.0
  216. - Project name in autogen.sh