@@ -239,6 +239,8 @@ static unsigned int compute_response_length(modbus_param_t *mb_param,
|
|
|
case FC_READ_EXCEPTION_STATUS:
|
|
|
length = 3;
|
|
|
break;
|
|
|
+ case FC_REPORT_SLAVE_ID:
|
|
|
+ return MSG_LENGTH_UNDEFINED;
|
|
|
default:
|
|
|
length = 5;
|
|
|
}
|
|
@@ -456,6 +458,8 @@ static uint8_t compute_query_length_header(int function)
|
|
|
function == FC_PRESET_MULTIPLE_REGISTERS)
|
|
|
/* Multiple write */
|
|
|
length = 5;
|
|
|
+ else if (function == FC_REPORT_SLAVE_ID)
|
|
|
+ length = 1;
|
|
|
else
|
|
|
length = 0;
|
|
|
|
|
@@ -471,6 +475,8 @@ static int compute_query_length_data(modbus_param_t *mb_param, uint8_t *msg)
|
|
|
if (function == FC_FORCE_MULTIPLE_COILS ||
|
|
|
function == FC_PRESET_MULTIPLE_REGISTERS)
|
|
|
length = msg[TAB_HEADER_LENGTH[mb_param->type_com] + 5];
|
|
|
+ else if (function == FC_REPORT_SLAVE_ID)
|
|
|
+ length = msg[TAB_HEADER_LENGTH[mb_param->type_com] + 1];
|
|
|
else
|
|
|
length = 0;
|
|
|
|